Ampere Hour Meter
IM 2500 Series Ampere Hour Meters are instruments for Battery Monitoring and Electroplating Applications.
Numerous options and features make it highly versatile and suitable for electroplating and battery maintenance. Use of timer control in such applications is highly inaccurate. AH meter replaces the timer giving precise control and many more facilities.
• Battery charge / discharge monitoring
• Rectifier on / off control
• Rectifier control while plating of metals like Gold / Silver / Nickel etc.
• Doser control for adding additives and brightner.
Features
• Microcontroller based highly versatile and reliable digital circuitry.
• Dust proof membrane keyboard for programming.
• Ampere Hour / Ampere Min or Ampere Min / Ampere Seconds selection from keyboard.
• Four digit display for current Amp Hour count and Current in Amperes
• One preset count with relay output at preset count.
• Shunt value programmable from keyboard.
• Floating decimal point, automatically selected depending on shunt value.
• Battery back up to retain count in case of power fail.
• External Reset input to reset count.
• DIN Panel Mount Size 96 x 96 x 150 mm
Models
IM2500 Series Ampere Hour meters are available in various models to suit almost all the requirements of electroplating and battery industry. Following model is ideally suitable for Electroplating application
Model IM2503 : Ampere hour minute meter with totaliser and Two Doser control relays for additive and brightner addition.
IM2509 : Ampere Hour minute meter with totaliser and Three Doser control relays
IM2508 : Ampere Hour Profile controller suitable for Battery formation
IM2510 : Ampere Hour meter with Timer
Following models are suitable for Electroplating as well as battery applications
IM2501 : 4 digit Ampere Hour – Ampere Minute – Ampere Seconds meter
IM2502 : 4 digit Ampere Hour – Ampere Minute – Ampere Seconds meter with 6 digit totaliser
IM2506 : 6 digit Ampere hour – Ampere Minute – Ampere Seconds meter
Following models are suitable specifically for Battery applications
IM2505 : Charge / Discharge Ampere Hour meter with AH count to track present battery charge
IM2507 : Ampere Hour meter with independent Charge and Discharge AH count
IM2511 : Charge Discharge Ampere Hour / Watt Hour meter with Voltage display
IM2512 : Ampere Hour Meter with Current limit for Rectifier control while battery charging
Following are modules available to enhance Ampere Hour Meter application
TE2504 : Stand alone Table top Cabinet with any of above Ampere Hour meter with terminations bought out for easy connection
IM2513 : Master Unit which can communicate with multiple Ampere Hour Meters suitable for applications to add additive and brightner in a tank with multiple rectifiers.